Description
Industrial-Grade Three-Phase Capacity
The Energydock Large 3Ø Energy Pod is a powerhouse solution for high-demand environments. Engineered with three Victron Multiplus II 48/5000 units, it provides a perfectly balanced continuous output of 15,000 VA (12,000 W). With a 9,000W peak power capacity per phase, this system is purpose-built to handle the heavy startup requirements of three-phase industrial machinery, irrigation pumps, and large-scale commercial HVAC systems.
Unrivaled Energy Endurance & Safety
Equipped with a massive 49.2kWh Storagedock LiFePO4 battery bank (960 Ah), this system offers an incredible 39.3kWh of usable energy at 80% Depth of Discharge. To manage this high-capacity storage safely, the Pod features a 1000A motorized and programmed circuit breaker and internal 300A module fuses, ensuring utility-grade protection for your energy investment.
Advanced Climate & Monitoring Suite
- Active Temperature Management: An integrated SDC 115-1 climate control unit (1500W cooling / 500W heating) regulates the internal environment. This ensures reliable operation in extreme temperatures from -40°C to 50°C, significantly extending the life of your lithium batteries.
- Professional Management: Includes the Victron Cerbo GX ensemble and GX Touch 70 display for advanced on-site control and 24/7 remote monitoring and diagnostics via the Victron Remote Management (VRM) portal.
- Large-Scale Enclosure: Housed in an expanded 2.5-meter ground-mountable metal enclosure (IP55), offering superior airflow and ample space for the high-capacity battery configuration.
Key Product Specifications
- Inverters: 3 x Victron Multiplus II 48/5000/70-50
- Battery Capacity: 49.2kWh (960 Ah) Total Energy
- Usable Energy: 39.3kWh (@ 80% DoD)
- Continuous Power: 15,000 VA / 12,000 W (5,000 VA per phase @ 25°C)
- Peak Power: 9,000 W per phase
- Climate Control: SDC 115-1 Unit (1500W Cooling / 500W Heating)
- Dimensions: 2524mm (L) x 960mm (W) x 1621mm (H)
- Warranty: 10-year warranty on Victron inverters, Cerbo GX, and Storagedock battery
| LARGE (4 BATTERY) 3Ø ENERGY POD GENERAL SPECIFICATIONS | |
|---|---|
| Product code | EPL3-15/49/M |
| Dimensions | 2524mm (length) x 960mm (width) x 1621mm (height) |
| Enclosure | Ground mountable metal enclosure |
| Installation | Indoor or outdoor |
| VICTRON MULTIPLUS II 48/5000/70-50 INVERTER/CHARGER (x3) | |
| PowerControl / PowerAssist | Yes |
| Transfer switch | 50 A per phase |
| Maximum AC input current | 50 A per phase |
| INVERTER | |
| DC input voltage range | 48 V – 38 – 66 V |
| Output | 230 VAC ± 2% / Frequency: 50 Hz ± 0.1% |
| Continuous output power at 25˚C | 5 000 VA / 4 000 W per phase |
| Continuous output power at 40˚/60˚C | 3 700 W / 3 000 W per phase |
| Max apparent feed-in power | 5000 VA per phase |
| Peak power | 9 000 W per phase |
| Maximum efficiency | 96% |
| Zero load power | 54 W |
| Zero load power in AES mode | 36 W |
| Zero load power in search mode | 6 W |
| CHARGER | |
| AC input | Input voltage range: 187 – 256 VAC / Input frequency: 45–65 Hz |
| Charge voltage absorption | 56.2 VDC |
| Charge voltage float | 56.2 VDC |
| Storage mode | 52.8 VDC |
| Maximum battery charge current | 70 A per phase DC |
| Battery temperature sensor | Yes |
| GENERAL | |
| Auxillary output | 32 A |
| Programmable relay | Yes |
| Protection | a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high |
| VE.Bus communication Port | For parallel & 3 phase operation, remote monitoring, system integration |
| General purpose com. Port | 2 x |
| Remote on-off | Yes |
| Operating temperature | -40 to +65°C fan assisted cooling / Humidity max 95% |
| STANDARDS | |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 |
| Emission, Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, EN-IEC61000-3-3 |
| VICTRON CERBO GX DEVICE – REMOTE MANAGEMENT & PROGRAMMING | |
| Supply voltage | 8 – 70 VDC |
| VE.Direct ports (always isolated) | 3 |
| VE.Bus (always isolated) | 2 paralleled RJ45 sockets |
| VE.Can | Yes – non isolated |
| Operating temperature range | -20 to +50°C |
| Cable length | 2 m |
| GX TOUCH 50 / GX TOUCH 70 | |
| Display Resolution | GX Touch 50: 800 x 480, GX Touch 70: 1024 x 600 |
| CLIMATE CONTROL UNIT | |
| Model | SDC 115 – 1 |
| Cooling Capacity | 1500 W |
| Voltage | DC 48V |
| Rated Power | 360 W |
| Refrigerant | R134a |
| Heating Capacity | 500 W |
| Working Temperature | -40 – 50°C |
| Noise | 62 dB |
| Weight | 26 kg |
| IP Rating | IP55 |
| STORAGEDOCK LV-COM 49.2/900 LiFePO₄ BATTERY | |
| Battery type | Grade A LiFePO₄ Prismatic cells |
| Nominal voltage | 51.2 VDC |
| Nominal capacity | 960 Ah |
| Total energy capacity | 49.2 kWh |
| Energy capacity at 80% DoD | 39.3 kWh |
| Maximum & constant current | 900 A |
| Maximum charge current | 915 A for 5 seconds |
| Maximum discharge current | 1065 A for 5 seconds / 915 A for 30 seconds |
| Protection | 1000 A motorized and programmed circuit breaker |
| Internal module fuse | 300 A (ANL) |
| Warranty cycle life | 6000 cycles @0.5C 80% depth of discharge |
| WARRANTIES | |
| Victron inverters | 10 year warranty |
| Victron Cerbo GX device | 10 year warranty |
| Storagedock battery | 10 years / 6000 cycles @ 80% DoD, whichever occurs first |
| Climate Control unit | 3 year warranty |