Description
Scalable Three-Phase Infrastructure
The Energydock Large 3Ø Energy Pod is designed for high-end applications where footprint and future-proofing are key. Utilizing three Victron Multiplus II 48/5000 units, the system provides a continuous output of 15,000 VA (12,000 W) balanced across all phases. With a 9,000W peak power capacity per phase, it is perfectly suited for heavy motor startups, commercial refrigeration, and large-scale HVAC systems.
Maximum Enclosure Volume & Durability
Standing at 2.5 meters in length, the Large enclosure (IP55 rated) provides superior airflow and extra internal volume. This ensures that even under heavy loads, the internal environment remains stable. The system is protected by a 1000A motorized and programmed circuit breaker, offering a level of electrical safety usually reserved for utility-grade installations.
Climate-Controlled Precision
- Active Temperature Management: Features an integrated SDC 115-1 climate control unit (1500W cooling / 500W heating). This unit maintains the internal temperature between -40°C and 50°C, shielding your lithium cells and Victron electronics from environmental extremes.
- Professional Management Suite: Includes the Victron Cerbo GX ensemble and a GX Touch 70 display. This allows for granular on-site control and 24/7 remote monitoring and diagnostics via the Victron Remote Management (VRM) portal.
- Grade A Storage: Powered by Storagedock LiFePO4 Prismatic cells, offering 13.1kWh of usable energy at 80% Depth of Discharge with a 6,000-cycle life.
Key Product Specifications
- Inverters: 3 x Victron Multiplus II 48/5000/70-50.
- Battery Capacity: 16.4kWh (320 Ah) Total Energy.
- Usable Energy: 13.2kWh (@ 80% DoD).
- Continuous Power: 15,000 VA / 12,000 W (5,000 VA per phase @ 25°C).
- Peak Power: 9,000 W per phase.
- Protection: 1000A motorized & programmed circuit breaker.
- Enclosure Dimensions: 2524mm (L) x 960mm (W) x 1621mm (H).
- Warranty: 10-year warranty on Victron inverters, Cerbo GX, and Storagedock battery.
| LARGE (4 BATTERY) 3Ø ENERGY POD GENERAL SPECIFICATIONS | |
|---|---|
| Product code | EPL3-15/16/M |
| Dimensions | 2524mm (length) x 960mm (width) x 1621mm (height) |
| Enclosure | Ground mountable metal enclosure |
| Installation | Indoor or outdoor |
| VICTRON MULTIPLUS II 48/5000/70-50 INVERTER/CHARGER (x3) | |
| PowerControl / PowerAssist | Yes |
| Transfer switch | 50 A per phase |
| Maximum AC input current | 50 A per phase |
| INVERTER | |
| DC input voltage range | 48 V – 38 – 66 V |
| Output | 230 VAC ± 2% / Frequency: 50 Hz ± 0.1% |
| Continuous output power at 25˚C | 5 000 VA / 4 000 W per phase |
| Continuous output power at 40˚/60˚C | 3 700 W / 3 000 W per phase |
| Max apparent feed-in power | 5000 VA per phase |
| Peak power | 9 000 W per phase |
| Maximum efficiency | 96% |
| Zero load power | 54 W |
| Zero load power in AES mode | 36 W |
| Zero load power in search mode | 6 W |
| CHARGER | |
| AC input | 187 – 256 VAC / Frequency: 45–65 Hz |
| Charge voltage absorption | 56.2 VDC |
| Charge voltage float | 56.2 VDC |
| Storage mode | 52.8 VDC |
| Max battery charge current | 70 A per phase DC |
| Battery temperature sensor | Yes |
| GENERAL | |
| Auxillary output | 32 A |
| Programmable relay | Yes |
| Protection | a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) input voltage ripple too high |
| VE.Bus communication Port | For parallel & 3 phase operation, remote monitoring, system integration |
| General purpose com. Port | 2 x |
| Remote on-off | Yes |
| Operating temperature | -40 to +65°C fan assisted cooling / Humidity max 95% |
| STANDARDS | |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1 |
| Emission, Immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3, EN-IEC 61000-3-3 |
| VICTRON CERBO GX DEVICE – REMOTE MANAGEMENT & PROGRAMMING | |
| Supply voltage | 8 – 70 VDC |
| VE.Direct ports (always isolated) | 3 |
| VE.Bus (always isolated) | 2 paralleled RJ45 sockets |
| VE.Can | Yes – non isolated |
| Operating temperature range | -20 to +50°C |
| Cable length | 2 m |
| GX TOUCH 50 / GX TOUCH 70 | |
| Display Resolution | GX Touch 50: 800 x 480, GX Touch 70: 1024 x 600 |
| CLIMATE CONTROL UNIT | |
| Model | SDC 115 – 1 |
| Cooling Capacity | 1500 W |
| Voltage | DC 48V |
| Rated Power | 360 W |
| Refrigerant | R134a |
| Heating Capacity | 500 W |
| Working Temperature | -40 – 50°C |
| Noise | 62 dB |
| Weight | 26 kg |
| IP Rating | IP55 |
| STORAGEDOCK LV-COM 16.4/300 LiFePO₄ BATTERY x4 | |
| Battery type | Grade A LiFePO₄ Prismatic cells |
| Nominal voltage | 51.2 VDC |
| Nominal capacity | 320 Ah x 4 = 1 280 Ah |
| Total energy capacity | 16.4 kWh x 4 = 65.6 kWh |
| Energy capacity at 80% DoD | 13.2 kWh x 4 = 52.8 kWh |
| Maximum & constant current | 300 A |
| Maximum charge current | 305 A for 5 seconds |
| Maximum discharge current | 355 A for 5 seconds / 305 A for 30 seconds |
| Protection | 1000 A motorized and programmed circuit breaker |
| Internal module fuse | 300 A (ANL) |
| Warranty cycle life | 6000 cycles @0.5C 80% depth of discharge |
| WARRANTIES | |
| Victron inverters | 10 year warranty |
| Victron Cerbo GX device | 10 year warranty |
| Storagedock battery | 10 years / 6000 cycles @ 80% DoD, whichever occurs first |
| Climate Control unit | 3 year warranty |